2014 Nissan Leaf - Power Supply, Ground & Circuit Elements (Section PG) (94 pages)

Model: 2014 Nissan Leaf
File size: 3.53 MB
Pages: 94 pages



Download Power Supply, Ground & Circuit Elements (Section PG)

Manual Description
POWER SUPPLY, GROUND & CIRCUIT ELEMENTS, precaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 5.

Precaution for Removing 12V Battery 6, fUSE BLOCK - JUNCTION BOX (J/B) 78, fUSE, FUSIBLE LINK AND RELAY BOX 79, iPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) 82.

Wiring Diagram — Battery Power Supply — 15, wiring Diagram — Accessory Power Supply — 23, bATTERY TERMINAL WITH FUSIBLE LINK 92, precaution for Technicians Using Medical Electric.

Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an.

Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such.

Implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor, room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.

The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.

The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- PG, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.

Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.

Automatically even when the power switch OFF state, because hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle hanRevision: May 2014, be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses parts, to prevent the removed service plug from being connected by mistake during procedure, always.

Carry it in your pocket or put it tool box, be sure to wear insulating protective equipment before beginning work on high voltage system, clearly identify the persons responsible for high voltage work and ensure that other persons do not, there is the possibility of a malfunction occurring if the vehicle is changed to READY status while.

HIGH VOLTAGE HARNESS AND EQUIPMENT IDENTIFICATION, the colors of the high voltage harnesses and connectors are all orange, applied to the Li-ion battery and other high voltage devices, hANDLING OF HIGH VOLTAGE HARNESS AND TERMINALS.

Immediately insulate disconnected high voltage connectors and terminals with insulating tape, rEGULATIONS ON WORKERS WITH MEDICAL ELECTRONICS, the vehicle contains parts that contain powerful magnets, pROHIBITED ITEMS TO CARRY DURING THE WORK.

Because this vehicle uses components that contain high voltage and powerful magnetism, due not carry any, metal products which may cause short circuits, or any magnetic media (cash cards, prepaid cards, etc, may be damaged on your person when working.