Download Body Control System (Section BCS)
Manual DescriptionPrecaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 3, precaution for Removing 12V Battery 4.
BODY CONTROL SYSTEM : Component Parts, bODY CONTROL SYSTEM : System Description 6, bODY CONTROL SYSTEM : Fail-safe 7, sIGNAL BUFFER SYSTEM : System Description 11.
COMMON ITEM : CONSULT Function (BCM COMMON ITEM)14, dOOR LOCK : CONSULT Function (BCM DOOR LOCK)15, rEAR DEFOGGER : CONSULT Function (BCM REAR DEFOGGER)15, bUZZER : CONSULT Function (BCM - BUZZER) 16.
INT LAMP : CONSULT Function (BCM - INT, hEADLAMP : CONSULT Function (BCM - HEAD, wIPER : CONSULT Function - WIPER18, fLASHER : CONSULT Function (BCM - FLASHER)19.
AIR CONDITIONER : CONSULT Function (BCM AIR CONDITIONER)20, iNTELLIGENT KEY : CONSULT Function (BCM INTELLIGENT KEY)20, cOMB SW : CONSULT Function (BCM - COMB, bCM : CONSULT Function (BCM - BCM)23.
IMMU : CONSULT Function (BCM - IMMU) 23, bATTERY SAVER : CONSULT Function (BCM BATTERY SAVER) 24, tRUNK : CONSULT Function (BCM - TRUNK) 25, tHEFT ALM : CONSULT Function (BCM THEFT) 25.
RETAINED POWER : CONSULT Function (BCM, sIGNAL BUFFER : CONSULT Function (BCM SIGNAL BUFFER) 26, aIR PRESSURE MONITOR : CONSULT Function, (BCM - AIR PRESSURE MONITOR) 26.
HV C/U CAN COMM 79, pOWER SUPPLY AND GROUND CIRCUIT 82, cONTROL UNIT (BCM) : Description 73, cONTROL UNIT (BCM) : Work Procedure 73.
CONFIGURATION (BCM) : Work Procedure 74, cONFIGURATION (BCM) : Configuration list 75, precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle.
Technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with.
Device manufacturer before starting charge operation, as radiated electromagnetic wave generated by PDM (Power Delivery Module) normal charge, operation may affect medical electric devices, a technician using a medical electric device such, implantable cardiac pacemaker or an implantable cardioverter defibrillator must not approach motor.
Room [PDM (Power Delivery Module)] at the hood-opened condition during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.
The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac.
Pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- BCS, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.