Download Power Supply, Ground & Circuit Elements (Section PG)
Manual DescriptionPOWER SUPPLY, GROUND & CIRCUIT ELEMENTS, wiring Diagram - BATTERY POWER SUPPLY, wiring Diagram - ACCESSORY POWER SUPPLY -28, wiring Diagram - ACCESSORY POWER SUPPLY FUSE No.
Wiring Diagram - ON POWER SUPPLY -30, wiring Diagram - ON POWER SUPPLY FUSE, precaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance.
(SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 5, precautions for Removing Battery Terminal 6, fUSE BLOCK - JUNCTION BOX (J/B) 37, wiring Diagram - BATTERY POWER SUPPLY - 16.
FUSE, FUSIBLE LINK AND RELAY BOX 38, iPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) 39, bATTERY TERMINAL WITH FUSIBLE LINK 102, how to Handle 12V Battery 96.
Precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts.
If a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may.
Effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.
The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION.
The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- PG, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect.
Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.
Automatically even when the power switch OFF state, since hybrid vehicles and electric vehicles contain a high voltage battery, there risk, electric shock, electric leakage, or similar accidents if the high voltage component vehicle, be sure to remove the service plug in order to disconnect the high voltage circuits before performing inspection or maintenance of high voltage system harnesses parts.
The removed service plug must always be carried in a pocket of the responsible worker placed, the tool box during the procedure to prevent the plug from being connected by mistake, be sure to wear insulated protective equipment before beginning work on high voltage system, never allow workers other than the responsible person to touch the vehicle containing high voltage.
Never bring the vehicle into the READY status with the service plug removed unless otherwise, hIGH VOLTAGE HARNESS AND EQUIPMENT IDENTIFICATION, all the high voltage harnesses and connectors are orange, include an orange high voltage label.
HANDLING OF HIGH VOLTAGE HARNESS AND TERMINALS, immediately insulate disconnected high voltage connectors and terminals with insulating tape, rEGULATIONS ON WORKERS WITH MEDICAL ELECTRONICS.