Download Interior (Section INT)
Manual DescriptionPrecaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, precautions for Removing Battery Terminal 4, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4.
Precaution for Procedure without Cowl Top Cover 5, iNSTRUMENT SIDE PANEL : Removal Installation20, fRONT PILLAR GARNISH : Removal Installation21, kICKING PLATE OUTER : Removal Installation22.
KICKING PLATE INNER : Removal Installation23, bODY SIDE WELT : Removal Installation24, dASH SIDE FINISHER : Removal Installation, cENTER PILLAR LOWER GARNISH : Removal.
CENTER PILLAR UPPER GARNISH : Removal, rEAR PILLAR FINISHER : Removal Installation26, sQUEAK AND RATTLE TROUBLE DIAGNOSES 8, rEAR PARCEL SHELF FINISHER : Removal.
LUGGAGE FLOOR BOARD : Removal Installation 36, lUGGAGE REAR PLATE : Removal Installation 36, lUGGAGE FLOOR UPPER FINISHER : Removal, lUGGAGE FINISHER MASK : Removal Installation 37.
LUGGAGE FLOOR FRONT FINISHER : Removal, lUGGAGE SIDE LOWER FINISHER : Removal, bACK DOOR UPPER FINISHER : Removal, bACK DOOR SIDE FINISHER : Removal Installation 42.
BACK DOOR PULL HANDLE : Removal Installation 43, bACK DOOR LOWER FINISHER : Removal, eMERGENCY LID : Removal Installation 44, precaution for Technicians Using Medical Electric.
Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an.
Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may, effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment.
(including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), H, avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.
The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD).
The electromagnetic wave of Intelligent Key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work.
The high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state.
When removing the 12V battery terminal, turn OFF power, switch and wait least 5 minutes, then a DTC detection error or ECU data corruption may occur.