2012 Nissan Leaf - Interior Lighting System (Section INL) (49 pages)

Model: 2012 Nissan Leaf
File size: 1.27 MB
Pages: 49 pages



Download Interior Lighting System (Section INL)

Manual Description
Precaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, precautions for Removing Battery Terminal 4, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 4.

Interior Lamp Appearance Bulb Specification 6, iNTERIOR ROOM LAMP CONTROL SYSTEM 8, iNTERIOR ROOM LAMP CONTROL SYSTEM , iNTERIOR ROOM LAMP BATTERY SAVER SYSTEM 10.

ILLUMINATION CONTROL SYSTEM : Circuit Diagram 14, aUTO LIGHT ADJUSTMENT SYSTEM : System, aUTO LIGHT ADJUSTMENT SYSTEM : Circuit, cOMMON ITEM : CONSULT Function (BCM COMMON ITEM)17.

INT LAMP : CONSULT Function (BCM - INT, bATTERY SAVER : CONSULT Function (BCM BATTERY SAVER)20, iNTERIOR ROOM LAMP CONTROL CIRCUIT, precaution for Technicians Using Medical Electric.

Parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts, if a technician uses a medical electric device such as an implantable cardiac pacemaker an.

Implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may, effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment.

(including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8, the electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker.

The implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), the electromagnetic wave of TCU might affect function, pRECAUTION AT INTELLIGENT KEY SYSTEM OPERATION, the electromagnetic wave of Intelligent Key might affect the function implantable cardiac.

Pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- M, able cardioverter defibrillator (ICD), the electromagnetic wave of Intelligent Key might affect, point to Be Checked Before Starting Maintenance Work.

The high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts, automatically even when the power switch OFF state.

When removing the 12V battery terminal, turn OFF power, switch and wait least 5 minutes, then a DTC detection error or ECU data corruption may occur, always disconnect the battery terminal within 60 minutes after.

OFF, the battery automatic charge control may automatically, start after a lapse of 60 minutes power switch OFF, disconnect battery terminal according following steps, check that EVSE not connected.

If EVSE is connected, the air conditioning system may be automatically activated by timer A/C function, if the battery is removed within 5 minutes after the power switch is turned OFF, plural DTCs may be, after all doors (including back door) are closed, if a door (including back door) opened before, battery terminals are disconnected, start over Step 1.

After turning the power switch OFF, if Remote A/C” is activated by user operation, stop air, conditioner and start over Step 1, once the power switch is turned ON → OFF, the 12V battery automatic charge control does not start.