2011 Nissan Leaf - Power Supply, Ground & Circuit Elements (Section PG) (107 pages)

Model: 2011 Nissan Leaf
File size: 5.09 MB
Pages: 107 pages



Download Power Supply, Ground & Circuit Elements (Section PG)

Manual Description
POWER SUPPLY, GROUND & CIRCUIT ELEMENTS, wiring Diagram - BATTERY POWER SUPPLY, wiring Diagram - ACCESSORY POWER SUPPLY -53, wiring Diagram - ACCESSORY POWER SUPPLY FUSE No.

Wiring Diagram - ON POWER SUPPLY -59, wiring Diagram - ON POWER SUPPLY FUSE, fUSE BLOCK - JUNCTION BOX (J/B) 81, precaution for Technicians Using Medical Electric 3.

Point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 5, precaution for Removing 12V Battery 6, fUSE, FUSIBLE LINK AND RELAY BOX 82.

IPDM E/R (INTELLIGENT POWER DISTRIBUTION MODULE ENGINE ROOM) 83, wiring Diagram - BATTERY POWER SUPPLY - 15, bATTERY TERMINAL WITH FUSIBLE LINK 105, how to Handle 12V Battery 99.

Precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts.

If a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may.

Effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.

The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator(ICD), the electromagnetic wave of TCU might affect function, precaution at intelligent key system operation.

The electromagnetic wave of intelligent key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- PG, able cardioverter defibrillator (ICD), the electromagnetic wave of intelligent key might affect the function of the device.

Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work, if the timer air conditioner or timer charge (during EVSE connection) is set, the high voltage system starts.

Automatically even when the power switch OFF state, because hybrid vehicles and electric vehicles contain a high voltage battery, there is the risk of electric shock, electric leakage, or similar accidents if the high voltage component and vehicle hanRevision: 2010 November, be sure to remove the service plug in order to shut off the high voltage circuits before performing, inspection or maintenance of high voltage system harnesses parts.

Does not accidentally connect it while work progress, be sure to wear insulating protective equipment consisting of glove, shoes face shield before, beginning work on high voltage system, clearly identify the persons responsible for high voltage work and ensure that other persons do not.

There is the possibility of a malfunction occurring if the vehicle is changed to READY status while, hIGH VOLTAGE HARNESS AND EQUIPMENT IDENTIFICATION, the colors of the high voltage harnesses and connectors are all orange, applied to the Li-ion battery and other high voltage devices.

HANDLING OF HIGH VOLTAGE HARNESS AND TERMINALS, immediately insulate disconnected high voltage connectors and terminals with insulating tape, rEGULATIONS ON WORKERS WITH MEDICAL ELECTRONICS.