2011 Nissan Leaf - Body Control System (Section BCS) (77 pages)

Model: 2011 Nissan Leaf
File size: 1.11 MB
Pages: 77 pages



Download Body Control System (Section BCS)

Manual Description
Precaution for Technicians Using Medical Electric 3, point to Be Checked Before Starting Maintenance, (SRS) "AIR BAG" and "SEAT BELT PRE-TENSIONER" 3, precaution for Removing 12V Battery 4.

BODY CONTROL SYSTEM : Component Parts, bODY CONTROL SYSTEM : System Description 6, sIGNAL BUFFER SYSTEM : System Description 10, cOMMON ITEM : CONSULT Function (BCM COMMON ITEM) 13.

DOOR LOCK : CONSULT Function (BCM DOOR LOCK)15, rEAR WINDOW DEFOGGER : CONSULT Function (BCM - REAR DEFOGGER)16, bUZZER : CONSULT Function (BCM - BUZZER) 16, iNT LAMP : CONSULT Function (BCM - INT.

HEADLAMP : CONSULT Function (BCM - HEAD, wIPER : CONSULT Function - WIPER21, fLASHER : CONSULT Function (BCM - FLASHER)22, iNTELLIGENT KEY : CONSULT Function (BCM INTELLIGENT KEY)23.

COMB SW : CONSULT Function (BCM - COMB, bCM : CONSULT Function (BCM - BCM)26, iMMU : CONSULT Function (BCM - IMMU)27, bATTERY SAVER : CONSULT Function (BCM BATTERY SAVER)27.

TRUNK : CONSULT Function (BCM - TRUNK) 28, tHEFT ALM : CONSULT Function (BCM THEFT) 29, rETAIND PWR : CONSULT Function (BCM - RETAINED PWR) 30, sIGNAL BUFFER : CONSULT Function (BCM SIGNAL BUFFER) 30.

HV C/U CAN COMM 67, aIR PRESSURE MONITOR : CONSULT Function, (BCM - AIR PRESSURE MONITOR) 30, pOWER SUPPLY AND GROUND CIRCUIT 70.

CONTROL UNIT (BCM) : Description 62, cONTROL UNIT (BCM) : Work Procedure 62, cONFIGURATION (BCM) : Work Procedure 63, cONFIGURATION (BCM) : Configuration list 64.

Precaution for Technicians Using Medical Electric, parts with strong magnet is used vehicle, technicians using a medical electric device such as pacemaker must never perform operation, vehicle, as magnetic field can affect the device function by approaching such parts.

If a technician uses a medical electric device such as an implantable cardiac pacemaker an, implantable cardioverter defibrillator, the possible effects on the devices must be checked with, device manufacturer before starting charge operation, as radiated electromagnetic wave generated by on board charger at normal charge operation may.

Effect medical electric devices, a technician using a medical electric device such as implantable cardiac pacemaker or an implantable cardioverter defibrillator must not enter vehicle compartment, (including luggage room) during normal charge operation, if a technician uses implantable cardiac pacemaker or implantable cardioverter defibrillator (ICD), avoid the device implanted part from approaching within approximately 220 mm (8.

The electromagnetic wave of TCU might affect the function of the implantable cardiac pacemaker, the implantable cardioverter defibrillator (ICD), when using service, etc, if a technician uses other medical electric devices than implantable cardiac pacemaker or implantable cardioverter defibrillator(ICD), the electromagnetic wave of TCU might affect function, precaution at intelligent key system operation.

The electromagnetic wave of intelligent key might affect the function implantable cardiac, pacemaker or the implantable cardioverter defibrillator (ICD), at door operation, each request, if a technician uses other medical electric devices than implantable cardiac pacemaker implant- BCS, able cardioverter defibrillator (ICD), the electromagnetic wave of intelligent key might affect the function of the device.

Point to Be Checked Before Starting Maintenance Work, the high voltage system may starts automatically, and timer charge (during EVSE connection) are not set before starting maintenance work.